人人澡人人干_日本高清一二三区_男人叫床声_放荡高辣h文绿帽

Sulphuric acid furnace bottom high pressure centrifugal fan

Sulphuric acid furnace bottom high pressure centrifugal fan

Product features:

Craftsmanship and Quality

精益設計 高效節能

Lean design Energy efficient

Advanced aerodynamic design and efficient motor systems provide stable and efficient air flow in various production processes. By optimizing airflow distribution and reducing energy loss, the Shuangjian blower can significantly improve energy efficiency.

嚴謹工藝 確保設備可靠性能

Rigorous process to ensure reliable performance of equipment

Shuangjian blower adopts strict standards and measures in quality control. From raw materials into the factory to finished products, every link has undergone strict quality testing and monitoring. Through advanced testing equipment.

國際化高標準配置

International high standard configuration

High quality accessory selection and reliability design provide sufficient equipment strength and durability for the Shuangjian blower, and reduce maintenance costs. Selection of domestic and foreign well-known brand accessories.

易于維護 提高設備作業率

Easy maintenance to improve equipment operation rate

The fan is equipped with sliding bearing, thin oil station, high fuel tank and a complete set of safety interlock protection system, and the shell is horizontally divided, and the fan inlet and outlet pipes are horizontally connected with the shell inlet.

數字化加工,精度更高

Digital processing, higher precision

Hubei Shuangjian has dozens of CNC machine tool production lines and robot welding equipment, from steel plate cutting, bending, planing, milling to painting, all realize digital control, high processing precision, some core components accurate.

原廠配件供應,運行后顧無憂

Original parts supply, running worry free

Hubei Shuangjian as a set of production and sales in one of the strength of the enterprise, we are responsible for their production of each piece of equipment, to provide customers.

 

Product Details

Model No. Transmission mode Rotation speed r/min No. Flow m3/h Full pressure kpa Internal efficiency % Internal power kW Required power KW Electromotor Coupling GB4323-87
(1 set)
 
Anchor bolt
GB799-76
(4)
Nut
GB52-76
(4)
Gasket
GB96-76
(4)
Model Power kw
9.2 D 2950 1 9310 19610 73.5 69.0 72.3 Y315S-2 110   M24×630 M24 24
2 11650 20210 77.6 84.3 84.3
3 13850 20030 77.8 99.1 99.1
4 16130 19340 76.3 113.5 113.5 Y315M2-2 160
5 18410 18850 74.1 130.1 130.1
6 20570 17950 70.5 145.4 145.4
7 22890 17050 65.8 164.7 164.7 Y315M3-2 185

 

Model No. Transmission mode Rotation speed r/min No. Flow m3/h Full pressure kpa Internal efficiency % Internal power kW Required power KW Electromotor Coupling GB4323-87
(1 set)
 
Anchor bolt
GB799-76
(4)
Nut
GB52-76
(4)
Gasket
GB96-76
(4)
Model Power kw
9.8 D 2950 1 9580 22600 73.5 81.7 84.9 JK2112-2 125   M24×630 M24 24
2 11810 23200 77.6 98.2 101.2
3 14000 23020 77.8 115.2 118.8
4 16400 22500 76.3 134.3 138.1 Y315M2-2 160
5 18610 22010 74.1 153.2 156.9
6 20720 20020 70.5 163.3 167.2
7 23050 19530 65.8 188.9 192.1 Y315L2-2 200
 

Product Atlas

Sulphuric acid furnace bottom high pressure centrifugal fan Sulphuric acid furnace bottom high pressure centrifugal fan

Product Parameters

Maintenance

維修保養

1. Daily inspection and maintenance

Appearance inspection: Check the appearance of the blower regularly to confirm that there is no damage, deformation or rust.

Running sound: Monitor the running sound of the blower. If there is abnormal sound, stop the machine immediately for inspection.

Vibration: Check the vibration of the blower regularly to ensure that it is within the allowed vibration range.

 

2.Lubrication system maintenance

Lubricating oil inspection: check the oil level and quality of lubricating oil regularly to ensure that it is within the specified range, and replace the deteriorated lubricating oil in time.

Grease replacement: For the parts that use grease, it is necessary to replace it regularly to ensure the lubrication effect.

 

3.Cooling system maintenance

Cooling water inspection: For the blower with water cooling, it is necessary to regularly check the flow rate and temperature of the cooling water to ensure that the cooling effect is good.

Cooler cleaning: Clean the cooler regularly to prevent its blockage affecting the heat dissipation effect.

 

4.Internal inspection and maintenance

Internal cleaning: Regularly clean the dust and debris inside the blower to avoid damage to the blower.

Fastener inspection: Check the fasteners inside the blower to ensure that they are tight and not loose.

 

5.Electrical system maintenance

Motor inspection: Check the running status of the motor regularly to ensure its normal operation.

Cable check: Check the connection and insulation of the cable to ensure that there is no damage or aging.

 

6.Shutdown and maintenance

Shutdown cleaning: When the blower is shut down, thoroughly clean the dust and dirt inside and outside the blower.

Downtime inspection: Use downtime to conduct a thorough inspection of the blower to find and deal with potential problems.

 

Through the attention and execution of these maintenance details of the blower, it can ensure its long-term stable operation, extend its service life, and improve production efficiency.

 
Design and development capability

Design and development capability

Our company has strong technical research and development capabilities, and has established several research workstations to bring sustained vitality to the improvement and progress of Shuangjian's technical research and development capabilities.

See more

嚴格檢測

Strict testing

Supporting auxiliary support technology and functional control technology for modern design and manufacturing of new wind turbines, establishing a network CAD system, using deformable simulation analysis software to achieve intelligent product design and process design.

See more

Quality assurance

Quality assurance

Our company has developed dozens of quality management documents in accordance with the requirements of the ISO9001:2000 quality management system, including the Quality Manual, Procedure Documents, Incoming Inspection Specification, Process Inspection Specification, Finished Product Inspection Specification, Equipment Operation Regulations, Assembly Operation Manual, and Test Equipment Operation Manual.

See more



Contact Us

We are willing to continue to cooperate sincerely with new and old friends at home and abroad with higher quality products and more comprehensive services, and create win-win results together as always!

Sales Hotline:

+86-722-6430098

Mobile version

WeChat official account

Add:Guangshui Economic Development Zone, Hubei Province

Tel:+86-722-6430098  +86-722-6430068

Tel:+86-18108610199

Email:sjxs@hbfj.cn