人人澡人人干_日本高清一二三区_男人叫床声_放荡高辣h文绿帽

4-72 B4-72 centrifugal fan

4-72 B4-72 centrifugal fan

Product features:

Craftsmanship and Quality

精益設計 高效節能

Lean design Energy efficient

Advanced aerodynamic design and efficient motor systems provide stable and efficient air flow in various production processes. By optimizing airflow distribution and reducing energy loss, the Shuangjian blower can significantly improve energy efficiency.

嚴謹工藝 確保設備可靠性能

Rigorous process to ensure reliable performance of equipment

Shuangjian blower adopts strict standards and measures in quality control. From raw materials into the factory to finished products, every link has undergone strict quality testing and monitoring. Through advanced testing equipment.

國際化高標準配置

International high standard configuration

High quality accessory selection and reliability design provide sufficient equipment strength and durability for the Shuangjian blower, and reduce maintenance costs. Selection of domestic and foreign well-known brand accessories.

易于維護 提高設備作業率

Easy maintenance to improve equipment operation rate

The fan is equipped with sliding bearing, thin oil station, high fuel tank and a complete set of safety interlock protection system, and the shell is horizontally divided, and the fan inlet and outlet pipes are horizontally connected with the shell inlet.

數字化加工,精度更高

Digital processing, higher precision

Hubei Shuangjian has dozens of CNC machine tool production lines and robot welding equipment, from steel plate cutting, bending, planing, milling to painting, all realize digital control, high processing precision, some core components accurate.

原廠配件供應,運行后顧無憂

Original parts supply, running worry free

Hubei Shuangjian as a set of production and sales in one of the strength of the enterprise, we are responsible for their production of each piece of equipment, to provide customers.

 

Product Details

4-72 B4-72 centrifugal fan
 

Brief introduction

4-72 centrifugal fan can be used as indoor ventilation for general factories and large buildings, conveying air and other non-spontaneous combustion, harmless to the human body, and non-corrosive to steel gases. B4-72 fan can be used for ventilation of flammable and volatile gases. No viscous substances are allowed in the gas, and the dust and hard particles contained are not more than 150mg/m3. The gas temperature shall not exceed 80℃. The performance and selection of B4-72 fan and the size of the foundation are consistent with that of 4-72 fan and can be selected according to its sample. The structure of the fan is basically the same as that of type 4-72. NO2.8 ~ 6A adopts the Electromotor of type B35 with flanges and foot, NO6 ~ 1 2C and DElectromotor adopt the YB series corresponding to the Y series in this table, and the installation type is B.

 

4-72 fan form

Facing from the Electromotor side, the impeller rotates clockwise, which is called right-handed fan, denoted by "right" : The impeller rotates counterclockwise, which is called left cyclone machine, denoted by "left". The outlet level of the fan is expressed by the outlet Angle of the housing. 4-72 fan №2.8 ~ 6 is made into a type when leaving the factory, and the user unit is installed into the required position according to the requirements, and it is not necessary to indicate when ordering. NO2.8 Air outlet position adjustment ranges from 0 to 225, with an interval of 45. No3.2 to 6 The position adjustment of the air outlet ranges from 0 to 225, with an interval of 22.5. No8 to 12 Air exhaust outlet position adjustment range is 0 to 225, interval is 45. Nol6, 20 air outlet position made of three fixed O, 90, l80, can not be adjusted, need to indicate when ordering.
The transmission mode of the fan is A, B, C and D. In the 4-72 fan, №2.8 ~ 6 adopts type A transmission, №6 ~ 12 adopts type c and D transmission, and №16 ~ 20 adopts type B transmission.

 

4-72 fan structure

The N2.8A ~ 6A in the 4-72 fan is mainly composed of direct connected motors distributed by the impeller, shell, air inlet and other parts. NO6 ~ 20 In addition to the above parts, there are transmission parts, etc.
(1) The impeller is composed of 10 receding airfoil blades, a curved front disk and a flat rear disk. Made of steel plate or cast aluminum alloy, and corrected by dynamic and static balance, air performance is good, high efficiency, smooth operation.
(2) The case is made into two different types. N02.8 ~ 12 chassis as a whole, can not be disassembled. The casing of NO1 6-20 is made of three open type, in addition to the two halves along the middle water plane, the upper half is vertically divided into two halves along the center line, and is connected by bolts.
(3) The air inlet is made of a whole, installed on the side of the fan, and the section parallel to the axis is a curve shape, which can make the gas enter the impeller smoothly, and the loss is small.
(4) The transmission part is composed of a spindle, a bearing box, a rolling bearing, a pulley or a coupling


 

4-72 fan parameter table

 
 

Model NO
Transmission mode
Rotational speed r/min
No.
Flow
Total pressure Pa
Internal efficiency %
Internal power kW
Required power kW
Electromotor
Foot bolt GB799-76(4)
Ground nut G86170-86(4)
Gasket GB96-85(4)
m3/S
m3/h
Model
Power kW
2.8
A
2900
1
O.314
1131
994
69.3
O.45
O.67
Y90S-2
(B35)
1.5
M8×220
M8
8
2
0.364
1310
966
73.2
0.48
0.72
3
O.411
1480
933
75.5
O.51
O.71
4
0.461
1659
887
76.8
O.53
0.74
5
0.508
1828
835
76.9
0.55
O.77
6
0.558
2007
770
75.6
O.57
O.79
7
0.605
2177
702
73.2
0.58
0.81
8
O.654
2356
606
69.3
O.57
O.80
3.2
A
2900
1
0.469
1688
1300
69.3
O.88
1.23
Y90L-2
(B35)
2.2
M8×220
M8
8
2
0.543
1955
1263
73.2
O.93
1.31
3
0.614
2209
1220
75.5
O.99
1.38
4
0.688
2476
1160
76.8
1.03
1.34
5
0.758
2729
1091
76.9
1.07
1.39
6
0.832
2996
1006
75.6
1.10
1.43
7
0.903
3250
918
73.2
1.13
1.47
8
O.977
3517
792
69.3
1.11
1.45
3.2
A
1450
1
0.234
844
324
69.3
O.11
O.16
Y90S-2
(B35)
1.1
M8×220
M8
8
2
O.272
978
315
73.2
O.12
O.17
3
0.307
1104
304
75.5
O.12
O.19
4
0.344
1238
289
76.8
O.13
0.19
5
0.379
1365
272
76.9
O.13
0.20
6
0.416
1498
251
75.6
O.14
O.21
7
O.451
1625
229
73.2
O.14
O.21
8
0.488
1758
198
69.3
O.14
0.21
3.6
A
2900
1
0.740
2664
1578
74.2
1.56
2.03
Y100L-2
(B35)
3
M10×220
M10
10
2
O.846
3045
1531
77.8
1.65
2.15
3
0.946
3405
1481
80.3
1.73
2.25
4
1.052
3786
1419
82.1
1.81
2.35
5
1.152
4146
1343
82.6
1.86
2.42
6
1.258
4527
1256
81.8
1.92
2.50
7
1.358
4887
1144
79.5
1.95
2.53
8
1.463
 
 
 
 
 
 

Product Atlas

4-72 B4-72 centrifugal fan 4-72 B4-72 centrifugal fan

Product Parameters

Maintenance

維修保養

1. Daily inspection and maintenance

Appearance inspection: Check the appearance of the blower regularly to confirm that there is no damage, deformation or rust.

Running sound: Monitor the running sound of the blower. If there is abnormal sound, stop the machine immediately for inspection.

Vibration: Check the vibration of the blower regularly to ensure that it is within the allowed vibration range.

 

2.Lubrication system maintenance

Lubricating oil inspection: check the oil level and quality of lubricating oil regularly to ensure that it is within the specified range, and replace the deteriorated lubricating oil in time.

Grease replacement: For the parts that use grease, it is necessary to replace it regularly to ensure the lubrication effect.

 

3.Cooling system maintenance

Cooling water inspection: For the blower with water cooling, it is necessary to regularly check the flow rate and temperature of the cooling water to ensure that the cooling effect is good.

Cooler cleaning: Clean the cooler regularly to prevent its blockage affecting the heat dissipation effect.

 

4.Internal inspection and maintenance

Internal cleaning: Regularly clean the dust and debris inside the blower to avoid damage to the blower.

Fastener inspection: Check the fasteners inside the blower to ensure that they are tight and not loose.

 

5.Electrical system maintenance

Motor inspection: Check the running status of the motor regularly to ensure its normal operation.

Cable check: Check the connection and insulation of the cable to ensure that there is no damage or aging.

 

6.Shutdown and maintenance

Shutdown cleaning: When the blower is shut down, thoroughly clean the dust and dirt inside and outside the blower.

Downtime inspection: Use downtime to conduct a thorough inspection of the blower to find and deal with potential problems.

 

Through the attention and execution of these maintenance details of the blower, it can ensure its long-term stable operation, extend its service life, and improve production efficiency.

 
Design and development capability

Design and development capability

Our company has strong technical research and development capabilities, and has established several research workstations to bring sustained vitality to the improvement and progress of Shuangjian's technical research and development capabilities.

See more

嚴格檢測

Strict testing

Supporting auxiliary support technology and functional control technology for modern design and manufacturing of new wind turbines, establishing a network CAD system, using deformable simulation analysis software to achieve intelligent product design and process design.

See more

Quality assurance

Quality assurance

Our company has developed dozens of quality management documents in accordance with the requirements of the ISO9001:2000 quality management system, including the Quality Manual, Procedure Documents, Incoming Inspection Specification, Process Inspection Specification, Finished Product Inspection Specification, Equipment Operation Regulations, Assembly Operation Manual, and Test Equipment Operation Manual.

See more



Contact Us

We are willing to continue to cooperate sincerely with new and old friends at home and abroad with higher quality products and more comprehensive services, and create win-win results together as always!

Sales Hotline:

+86-722-6430098

Mobile version

WeChat official account

Add:Guangshui Economic Development Zone, Hubei Province

Tel:+86-722-6430098  +86-722-6430068

Tel:+86-18108610199

Email:sjxs@hbfj.cn